Mitsubishi Electric MELDAS C6 Interface Manual page 138

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
M FUNCTION STROBE 4
[Function]
This signal informs that the 4th set of M function (M code) is specified in automatic operation.
[Operation]
The signal turns ON when:
(1) Four or more M function commands (M code) are specified in one block in automatic operation
(memory or MDI).
The signal turns OFF when:
(1) "M function finish 1" signal (FIN1) or "M function finish 2" signal (FIN2) turns ON.
(2) Reset condition occurs.
Other details are the same as those of "M function strobe 1" signal (MF1). Refer to "M function
strobe 1".
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
MF4
6-1-49
1st system
2nd system
X647
X6C7
3rd system
X747

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents