6H-12 CHARGING SYSTEM
1. Battery
2. Positive cable
3. Negative cable
4. Retainer
1. "B" terminal
2. Generator
3. Generator adjusting arm reinforcement
4. Bolt A
5. Bolt B
6. Generator adjusting arm
7. Pivot bolt
GENERATOR
REMOVAL
1) Disconnect negative cable at battery.
2) Disconnect "B" terminal wire and coupler from generator.
3) Remove generator adjusting arm reinforcement.
Loosen bolts A and remove generator (water pump) belt.
4) Remove bolts B and pivot bolt.
5) Remove generator together with generator adjusting arm, and
remove generator adjusting arm from generator.
INSTALLATION
Reverse above procedure giving specified tension to drive belt.
Refer to "Generator (Water Pump) Belt" for belt tension.
Tightening Torque
(a): 23 N·m (2.3 kg-m, 16.5 lb-ft)
(b): 50 N·m (5.0 kg-m, 36.5 lb-ft)