13) After applying sealant to part "A" as shown in figure at the left,
install CMP sensor case to cylinder head and tighten its fixing
bolts to specified torque.
"A" Sealant: 99000-31110
Tightening Torque
(a): 11 N
Connect CMP sensor connector.
1. O-ring
14) Adjust valve clearance as previously outlined.
15) Install cylinder head cover.
16) Refill cooling system and bleed air from system referring to
Section 6B.
17) Adjust generator belt tension, referring to BELT TENSION IN-
SPECTION in Section 6H.
18) Connect negative cable at battery.
19) Upon completion of installation, verify that there is no coolant
leakage at each connection.
20) Confirm that ignition timing is within specification referring to
Section 6F.
.
m (1.1 kg-m, 8.0 lb-ft)