4.3 CONTROLLER BOARD SELF-DIAGNOSTIC TEST

To start the self-diagnostic test:
1. Switch the machine off.
NOTE: If the Centronics interface is installed on the controller, attach the
Centronics loopback connector.
2. Press and hold down !!.
3. Switch the machine on. The initial screen is displayed.
• When the test ends, a self-diagnostic test report prints automatically. The
size of the paper, index, and counter print are selected automatically at the
same time. The paper size selection priority is as follows:
A4 LEF ! A4 SEF ! LT LEF ! LT SEF ! B4 ! LG ! A3 ! DLT
• If paper is not available for the printed report, the machine automatically
returns to normal operation mode. After supplying paper to the machine,
execute SP5990 005 to print the report. (The report does not print by cycling
the machine off and on.)
4. After the report prints, cycle the machine off and on.