BULLETIN NUMBER:
APPLICABLE MODEL:
GESTETNER – 6002/7502
RICOH – AFICIO 1060/1075
SAVIN – 2560/2575
SUBJECT: INSTALLATION NOTE FOR PRINTER/SCANNER DIMM
GENERAL:
Important Installation Note:
The following is the correct procedure for inserting ROM DIMMs to the controller board. Incorrect insertion
can damage the controller board or cause a bad connection between the DIMM and controller contacts. If
the upper contact is pressed in and bent, the resulting poor connection could cause the entire system not to
operate.
Inserting the ROM DIMM:
1. Hold the ROM DIMM with the edge connector [A] pointing toward the slot and the notch [B] on the DIMM
in the upper right-hand corner.
2. Insert the edge connector [C] into the slot at a 30-degree angle from the surface of the board.
NOTE:
If the angle is too low, the upper contact could bend.
3. Move the outside edge of the ROM DIMM up and down slightly until it works into the connector, then
gently press it down level with the controller board.
The above information is mentioned in the B064/B065 Service Manual (1.10.2) and on the sheet in the
Printer/Scanner Kit. Normally, the controller cannot be damaged if the above procedure is followed correctly,
however to further ensure damage does not result, the connector has been changed.
   
Copyright
2003 RICOH Corporation. All rights reserved.
TECHNICAL SERVICE BULLETIN
B064/B065 – 020
[A]
[B]
[C]
01/29/2003