1.13.4 SP MODE SETTINGS FOR IEEE 1394
The following SP commands can be set for IEEE 1394.
To enter the SP mode:
1. Press Clear Modes
2. On the operation panel keypad, press #$%.
3. Hold down Clear/Stop & for more than 3 seconds.
4. Press "Copy SP" on the touch-panel to open the SP command selection
screen.
SP Mode (Service)
SP1XXX
SP2XXX
SP3XXX
SP4XXX
SP5XXX
SP6XXX
SP7XXX
SP8XXX
5. Enter ,-*(.
SP No.
5839 004
5839 007
5839 008
5839 009
5839 010
5839 011
5839 012
5839 013
SM
"
Open All
Close All
Feed
Drum
Process
Scanner
Mode
Periphs
Data Log
Data Log2
Name
Device Name
Sets the names for all the physical devices connected to
the IEEE 1394 firewire network.
Cycle Master
Enables or disables cycle master function of the IEEE 1394
standard bus.
Sets the BCR (Broadcast Channel Register) setting for the
BCR Mode
Auto Node operation for the standard IEEE1394 bus for
when IRM is not in use. Three settings are available: 00,
01, 11.
IRM 1394a Check
Determines whether an IRM check for IEEE 1394 is
conducted for the Auto Node when IRM is not used.
Enables the "Node_Unique_Id" setting for enumeration on
Unique ID
the standard IEEE 1394 bus.
Logout
Determines how successive initiator login in requests are
handled during login for SBP-2.
Login
Enables or disables exclusive login for SBP-2.
Sets the limit for the number of logins for SBP-2. Range: 1
Login MAX
~ 62.
IEEE1394 (G336) FIREWIRE INTERFACE
Copy Window
SP Direct
X-XXX-XXX
COPY: SP1-001-001
Group
Page
Line
21
Line
Initial
0
Page
Group
Prev Page
Function
1-55
14APR 2002 03:25
Exit
Next Page
B064I999.WMF