BULLETIN NUMBER:
APPLICABLE MODEL:
GESTETNER – 6002/7502
RICOH – 1060/1075
SAVIN – 2560/2575
SUBJECT: FUSING WEB IS WRAPPED PREMATURELY
GENERAL:
Target machines:
BCU firmware v3.12, 9-bin Mailbox installed.
1. If SC550 occurs:
Update to v3.14 or later, replace the Fusing Web and reset SP1902-001 to a value of 0.
2. If SC550 does not occur, but firmware is still at v3.12:
Check the value of SP1902-002. If its default has not been changed (60cpm: 18, 75cpm: 15), simply
update to v.314 or later.
If the default has been changed, this means the web has been advanced prematurely at least once, so
check the web itself and estimate the actual percent of web used. Input the estimated % into SP1902-
001, then update to v3.14 or later.
3. If SC500 does not occur, but firmware has already been updated to v3.14 or later:
Since the default for SP1902-002 has been set to its proper value with the firmware update, check the
web itself and input the estimated value into SP1902-001 as described in #2 above.
Copyright
2003 RICOH Corporation. All rights reserved.
TECHNICAL SERVICE BULLETIN
B064/B065 - 025