3 Part Names and Functions
3-1-5
Operation Indicators When BOOTP Server Connection Fails
If using the BOOTP client is enabled, the Reader/Writer queries the BOOTP server at startup. If con-
necting to the server is not possible within a specific period of time or a suitable IP address is not avail-
able, the NORM/ERR indicators will flash irregularly.
The RUN indicator flashes green at 0.1-s intervals.
The LINK/ACT indicator lights.
The NORM/ERR indicators flash red irregularly
(twice every second).
3-1-6
Operation Indicators during Command Execution
Communications Command Execution
The RF indicator will light yellow during communications between the Reader/Writer and RF Tag for
execution of a command from the host device.
The RUN indicator lights green.
The RF indicator lights yellow.
Normal Command Completion
The NORM/ERR indicators will flash green once when processing ends normally for execution of a
command from the host device.
The RUN indicator lights green.
The NORM/ERR indicators flash green once.
NORM/ERR: Green
3 - 6
NORM/ERR: Red
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
RUN: Green
LINK/ACT: Lit.
NORM/ERR: Red
NORM/ERR: Red
RUN: Green
RF: Yellow
RUN: Green
NORM/ERR: Green
NORM/ERR: Green
NORM/ERR: Green
NORM/ERR: Red
TM
) (Z402)