GET CHANNEL
Function
This command is used to check the channel settings that are set in the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
RespData/Response Data
Channel
*1. Fixed channels can be acquired only in the models for JP. In the other models, the channels are fixed auto-
matically.
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Data type
Size
WORD
2 bytes
3006 hex
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Data type
Size
WORD
2 bytes
Error code
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
WORD
2 bytes
Expresses the channel.
[For JP]
0000 hex: Auto
0005 hex: 5 CH
000B hex: 11 CH
0011 hex: 17 CH