Omron V780-Series User Manual page 180

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

7 Ethernet/IP Communications
RESET
Function
This command restarts the entire Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
Response Area
Signal/data
ErrCode/Command Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
Note In the case of a forced reset, restart is performed without any output in the response area. During a
reboot, an output is performed in the response area.
7 - 28
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Function
1002 hex
Options
0000 hex: Reboot (Normal start)
0001 hex: Reboot (Safe Mode start)
FFFE hex: Forced reset (SAFE Mode start)
FFFF hex: Forced reset (Normal start)
Reboot: Reset is performed after the
Reader/Writer is set to an idle state.
Forced reset: Reset is performed immediately
when the command is received, without waiting
for the Reader/Writer to be set to an idle state.
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Function
Error code
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (Not used.)
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
TM
) (Z402)

Advertisement

Table of Contents
loading

Table of Contents