Omron V780-Series User Manual page 202

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

7 Ethernet/IP Communications
SET RF TAG SELECTION FILTER CONDITIONS
Function
This command sets the RF Tag selection filter conditions for the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
RF Tag selec-
tion
filter conditions
*1. If the RF Tag selection filter conditions settings are disabled, this value is always 0000 hex.
*2. Address 1000 hex specifies the "UII (EPC)_CRC-16" area of the RF Tag. Since this area varies depending on
the EPC code, care must be taken during use.
Response Area
Signal/data
ErrCode/Command Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
7 - 50
Data type
WORD
WORD
WORD
WORD
WORD
Enable/dis-
WORD
able
*1
WORD
Address
Data
WORD
*1
length
ARRAY[]
*1
Data
OF WORD
Data type
WORD
WORD
WORD
WORD
WORD
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Size
2 bytes
300B hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
2 bytes
Specifies whether to enable or disable RF Tag
selection filter conditions.
0000 hex: Disable
0001 hex: Enable
Default setting: 0000 hex
2 bytes
Specifies the address (in words) of the RF Tag to check.
1000 to 17FF hex: UII (EPC) area
2000 to 27FF hex: TID area
3000 to 3FFF hex: User area
* You cannot specify 0000 to 07FF hex
(reserved area).
Default setting: 0000 hex
2 bytes
Specifies the number of words of data to check.
Setting range: 0000 to 0010 hex
Default setting: 0000 hex
16 words
Specifies the data to check. (16 words)
(32 bytes)
* Fill unused data with 0000 hex.
* In compliance with Gen2 standards, bits 0
to 255 are masked, so the last bit of word
16 (bit 256) is ignored.
Default setting: 00..00 hex
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Function
*2
Function
TM
) (Z402)

Advertisement

Table of Contents
loading

Table of Contents