Executing the RESET Command (Reboot)
EXE
Command code
Command
Command
Area
parameters
Command data
Update counter
response
READY
BUSY
NORM
ERR
Response
Area
Update counter
Error code
Response
information
Response data
1.
The command code, command parameters, and command data are set from the PLC while the READY sig-
nal is ON. The value of the update counter response is matched with the value of the Update counter in the
V780 response area.
2.
The user (PLC) turns ON the EXE signal. This tells the Reader/Writer to start execution.
3.
When the Reader/Writer receives the instruction to start execution, it turns OFF the READY signal and turns
ON the BUSY signal.
4.
If the Reader/Writer can be reset, it sets the error code, response information, and response data, adds 1
(increments) to the update counter value, and then turns ON the NORM signal.
5.
The user (PLC) detects a change in the update counter value, and confirms that the NORM signal has turned
ON. Thereafter, the user (PLC) updates the update counter response value in accordance with the value of
the Update counter in the V780 response area, and turns OFF the EXE signal. This tells the Reader/Writer to
stop execution.
6.
When the Reader/Writer receives the instruction to stop execution, it resets itself. If the connection of the tag
data link is established after the Reader/Writer restarts, the READY signal turns ON and the BUSY signal
turns OFF.
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
0000 hex
0000 hex
1 2 3
4
5
7 Ethernet/IP Communications
0001 hex
0001 hex
6
TM
) (Z402)
0000 hex
7
7 - 83