Entry name
RSSIFilterEnable
Gives the enable/disable setting of the RSSI
filter.
It is set to true or false.
true: Enable
false: Disable
RSSIFilterHigh
Gives the setting of the high threshold for the
RSSI filter. It is set to 0 or from -10 to -70
Threshold
decimal.
RSSIFilterLow
Gives the setting of the low threshold for the
RSSI filter. It is set to 0 or from -10 to -70
Threshold
decimal.
RFTagSelectFilter
Gives the enable/disable setting of the RF
Tag selection filter.
Enable
It is set to true or false.
true: Enable
false: Disable
RFTagSelectFilter
Gives the memory address setting for the RF
Tag selection filter. It is specified in four hexa-
MemoryAddress1
decimal digits.
RFTagSelectFilter
Gives the setting of the data length in words
for the RF Tag selection filter. It is set to 0 to
Size1
16 decimal.
RFTagSelectFilter
Gives the setting of the verification data for
the RF Tag selection filter. It is specified in 64
VerificationData1
hexadecimal digits (16 words).
Smoothing Buffer
This is the number of smoothing buffer when
the communication mode is set to repeat.
RegistrationNumber
It must be specified as a decimal number.
LEDCustomNomal
Gives the custom indicator setting for a nor-
mal command (NORM).
It is set to -1 (not lit) or from 1 to 7 (individual
colors) decimal.
LEDCustomError
Gives the custom indicator setting for a com-
mand error (ERROR).
It is set to -1 (not lit) or from 1 to 7 (individual
colors) decimal.
LEDCustomWarning
Gives the custom indicator setting for unsta-
ble communications (WARNING).
It is set to -1 (not lit) or from 1 to 7 (individual
colors) decimal.
8 Browser Interface
Description
TM
) (Z402)
Default
false
0
0
false
0000
0
00...00
1024
1 (green)
8
2 (red)
3 (yellow)
8 - 43