8-2-11 Configuration File - Omron V780-Series User Manual

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

8-2-11 Configuration File

This section describes the format of the configuration file. The configuration file uses a normal INI file
format.
• Any line that starts with a semicolon (;) is treated as a comment.
• Any line that starts with an opening bracket ([) is treated as a section declaration row. The row must
also end in a closing bracket (]).
• Any row that does not start with either of the above two characters is an entry row.
Section and Entry Table
Section name
NetworkSetting
RFCommunication-
Setting
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Entry name
IPAddressSetting
Gives the IP address setting method for the
Method
Reader/Writer.
Specify a decimal value.
0000: Fixed setting
0001: Obtain from BOOTP server
0002: Get from BOOTP server as fixed set-
tings
IPAddress
Gives the setting of the IP address of the
Reader/Writer. It is given as four decimal
numbers separated by periods.
SubnetMask
Gives the setting of the subnet mask of the
Reader/Writer. It is given as four decimal
numbers separated by periods.
GatewayAddress
Gives the setting of the default gateway of
the Reader/Writer. It is given as four decimal
numbers separated by periods.
DeviceName
Gives the name of the Reader/Writer. It is
given in up to 63 ASCII characters.
WebPort
Gives the Ethernet communications port
number for the browser interface. It is set to
1024 to 65535 decimal.
WebPassword
Gives the login password for the browser
interface. It is specified in up to 15 ASCII
characters. "" (blank) is specified for no pass-
word.
RFCommunication
Gives the RF communications mode setting.
It is specified as a decimal value.
Mode
0: Once
1: Auto
2: Focus
3: Repeat
RFCommunication
Gives the communications speed between
the Reader/Writer and RF Tags. It is speci-
Speed
fied as a decimal value.
0: Auto speed
1: High speed
2: Normal speed
RFCommunication
Gives the RF communications timeout time.
It is specified as a decimal value.
Timeout
8 Browser Interface
Description
TM
) (Z402)
Default
0000
192.168.1.200
255.255.255.0
192.168.1.254
(Not set.)
8
7090
(Not set.)
0
0
250
8 - 41