Omron V780-Series User Manual page 212

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

7 Ethernet/IP Communications
GET FIRMWARE VERSION
Function
This command reads the firmware version of the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter Response
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo1/Response Information 2
RespInfo1/Response Information 3
Cnt/Update Counter
RespData/Response Data
Firmware
version
7 - 60
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
Run mode program
WORD
major version
Run mode program
WORD
minor version
Run mode program
WORD
revision
Safe mode program
WORD
major version
Safe mode program
WORD
minor version
Safe mode program
WORD
revision
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Data
Size
type
2 bytes 4002 hex
2 bytes 0000 hex (Not used.)
2 bytes 0000 hex (Not used.)
2 bytes 0000 hex (Not used.)
2 bytes 0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Data
Size
type
2 bytes Error code
2 bytes 0000 hex (Not used.)
2 bytes 0000 hex (Not used.)
2 bytes 0000 hex (Not used.)
2 bytes 0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
2 bytes 0000 to 0099 hex (BCD)
2 bytes l0000 to 0099 hex (BCD)
2 bytes 0000 to 9999 hex (BCD)
2 bytes 0000 to 0099 hex (BCD)
2 bytes 0000 to 0099 hex (BCD)
2 bytes 0000 to 9999 hex (BCD)
Function
Function
TM
) (Z402)

Advertisement

Table of Contents
loading

Table of Contents