7 Ethernet/IP Communications
GET TIME INFORMATION
Function
This command is used to check the time information from the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo1/Response Information 2
RespInfo1/Response Information 3
Cnt/Update Counter
RespData/Response Data
Time informa-
tion
7 - 62
Data type
WORD
WORD
WORD
WORD
WORD
Data type
WORD
WORD
WORD
WORD
WORD
Actual time
BYTE
flag
Hour
BYTE
Minutes
BYTE
Seconds
BYTE
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Size
2 bytes
4006 hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
1 byte
This byte indicates whether the actual time
was set from the host device.
0: The time has not been set, so the time
information gives the running time since the
power supply to the Reader/Writer was
turned ON.
1: The time was set, so the time information is
the drive time from the time set from the
host device.
1 byte
Hour
0 to 23
1 byte
Minutes
0 to 59
1 byte
Seconds
0 to 59
Function