Omron V780-Series User Manual page 139

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

4
Place a check mark to enable the Multi-Reader/Writer mode. Then, specify the IP addresses for
the slave Reader/Writers (3 units), and press the Set Button. This will restart the master
Reader/Writer.
5
When the master Reader/Writer has restarted, it will perform connection processing with each
of the registered slave Reader/Writers. The RUN indicator will change to yellow, which con-
nected as slave Reader/Writers.
6
The master Reader/Writer will establish communications with all of the slave Reader/Writers,
completing connection processing. You can check the Status of Multi-Reader/Writer setting view
that completed connection.
7
After this, the multiple Reader/Writers shall jointly operate by the issuing of communications
commands from the host device to the master Reader/Writer.
Precautions for Correct Use
• The Multi-Reader/Writers shall repeat connection processing if communications are not
established with the registered slave Reader/Writers, and connection processing is not com-
pleted (IP address specification error, Reader/Writer non-startup, etc.). The NORM/ERR indi-
cator will light red at a specific interval until connection processing is completed.