GET RSSI FILTER CONDITIONS
Function
This command is used to check the RSSI filter conditions that are set in the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo1/Response Information 2
RespInfo1/Response Information 3
Cnt/Update Counter
RespData/Response Data
RSSI
filter conditions
*1. If the RF Tag selection filter conditions settings are disabled, this value is always 0000 hex.
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Data type
WORD
WORD
WORD
WORD
WORD
Data type
WORD
WORD
WORD
WORD
WORD
Enable/dis-
WORD
able
HIGH
WORD
*1
Threshold
LOW
WORD
*1
Threshold
7 Ethernet/IP Communications
Size
2 bytes
300E hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
2 bytes
Expresses whether the RSSI filter is enabled
or disabled.
0000 hex: Disable
0001 hex: Enable
Default setting: 0000 hex
2 bytes
Expresses the high threshold for the reception
level.
FFBA to FFF6 hex
(0 or -70 to -10) [dBm]
Default setting: 0000 hex
2 bytes
Expresses the low threshold for the reception
level.
FFBA to FFF6 hex
(0 or -70 to -10) [dBm]
Default setting: 0000 hex