7 Ethernet/IP Communications
SET TRANSMISSION TIME
Function
This command sets the time to stop the transmission power.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
Stop time
Continuous transmission time
*1. To specify the stop time in the JP version, be sure to specify the continuous transmission time to other than
infinite (0000 hex). A command parameter error will occur if only either one of stop time or continuous trans-
mission time is set to 0.
The stop time cannot be set to 0000 hex in models other than those for JP.
7 - 54
Data type
WORD
WORD
WORD
WORD
WORD
WORD
*1
WORD
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Size
2 bytes
300F hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
2 bytes
Specifies the time to pause output during
transmission command execution.
For JP
0000 hex, 000A to 03E8 hex
(0000 hex is either None, or 10 to 1,000)
[msec]
Default setting: 0000 hex
For US
000A to 03E8 hex
(10 to 1,000 [msec])
Default setting: 000A hex
2 bytes
Specifies the maximum time to continuously
output radio waves during communications
command execution.
*1
For JP
0000 hex, 0190 to 2710 hex
(0000 hex is either No limit, or 400 to 10,000)
[msec]
Default setting: 0000 hex
Other than for JP
Always 0000 hex
Function
TM
) (Z402)