DATA FILL
Function
This command writes the specified data to the specified number of words beginning from the speci-
fied write start address. The specifications are made in the command.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
Fill data
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Data type
Size
WORD
2 bytes
0006 hex
WORD
2 bytes
First word address of the data to write to the
RF Tag (in words)
0000 to 07FF hex: Reserved area
1000 to 17FF hex: EPC area
2000 to 27FF hex: TID area
3000 to 3FFF hex: User area
WORD
2 bytes
Specify in 4-digit hexadecimal the number of
words of data to fill.
Setting range: 0000 hex or 0001 to 0800 hex
• If 0000 hex is specified for the number of fill
• You cannot write data to more than one
WORD
2 bytes
0000 hex (Not used.)
WORD
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
WORD
2 bytes
Fill data to write to the RF Tag (always one
word)
TM
) (Z402)
7 Ethernet/IP Communications
Function
words, the entire memory area will be filled.
area with the same command.
7
7 - 21