7 Ethernet/IP Communications
GET TRANSMISSION TIME
Function
This command is used to check the transmission times that are set in the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
RespData/Response Data
*1
Stop time
Continuous transmission time
7 - 56
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Function
3010 hex
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Function
Error code
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (Not used.)
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Expresses the time to pause output during
transmission command execution.
For JP
0000 hex, 000A to 03E8 hex
(0000 hex is either None, or 10 to 1,000)
[msec]
Default setting: 0000 hex
For US
000A to 03E8 hex
(10 to 1,000 [msec])
Default setting: 000A hex
Expresses the maximum time to continuously
output radio waves during communications
command execution.
*1
For JP
0000 hex, 0190 to 2710 hex
(0000 hex is either No limit, or 400 to 10,000)
[msec]
Default setting: 0000 hex
Other than for JP
Always 0000 hex
TM
) (Z402)