6-10 Multi-Reader/Writer Function; 6-10-1 Outline - Omron V780-Series User Manual

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

6 Functions

6-10 Multi-Reader/Writer Function

6-10-1 Outline

The Multi-Reader/Writer function allows connection to multiple Reader/Writers, and performs com-
munications with RF Tags.
It can connect to a maximum of eight Reader/Writers, and performs master/slave control with one
Reader/writer as the master, and the other Reader/Writers as slaves. Because multiple slave
Reader/Writers can be jointly controlled simply by controlling a master Reader/Writer, it is possible
to easily perform complicated controls from the host device.
Slave Reader/Writer
Slave Reader/Writer
(Reader/Writer No.7)
(Reader/Writer No.2)
...
Control
In the Multi-Reader/Writer function, the slave Reader/Writers connected to the master Reader/Writer
are differentiated by the following Reader/Writer numbers.
Reader/Writer Type
Master Reader/Writer
Slave Reader/Writer 1
Slave Reader/Writer 2
Slave Reader/Writer 3
Slave Reader/Writer 4
Slave Reader/Writer 5
Slave Reader/Writer 6
Slave Reader/Writer 7
Precautions for Correct Use
• When using this function, the Reader/Writers connected by the Multi-Reader/Writer function
must all be Version 3.0 or later.
• When using this function, the Reader/Writers connected by the Multi-Reader/Writer function
must all be the same model.
• The Slave Reader/Writer does not accept communications commands or Reader/Writer set-
ting commands.
Also, it does not accept connection from other than the Master Reader/ Writer.
*1. Getting command will be accepted.
*2. Connection from the web port will be accepted.
6 - 58
Slave Reader/Writer
(Reader/Writer No.1)
RF Tag
Control
Control
Reader/Writer Number
0
1
2
3
4
5
6
7
* 1
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Host device
(PLC, etc.)
Command
Response
Switching Hub
Remarks
The Reader/Writer numbers are not used when the
Multi-Reader/Writer function is disabled.
The Reader/Writer numbers will be moved forward by the
number of slave Reader/Writers. (Configuration with middle
numbers missing is not possible)
Master Reader/Writer
(Reader/Writer No.0)
* 2
TM
) (Z402)

Advertisement