7 Ethernet/IP Communications
SET DEVICE NAME
Function
This command is used to set or clear a name for the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
Device name
*1. The device name is given with ASCII characters 20 hex (space) to 7E hex (~).
Response Area
Signal/data
ErrCode/Command Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
7 - 32
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
ARRAY[]
64 bytes
OF BYTE
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Function
200B hex
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
*1
ASCII characters
, 64 bytes max.
(Filled with up to 63 ASCII characters plus the
end code (00 hex))
Specify 00 hex for all bytes to clear the device
name.
Default setting: 00 hex for all bytes
Function
Error code
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (Not used.)
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
TM