Omron V780-Series User Manual page 166

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

7 Ethernet/IP Communications
ID WRITE
Function
This command writes the ID code to the RF Tag in the communications range.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
RespData/Response Data
ID Data
7 - 14
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
ARRAY[]
Max
OF WORD
31 words
62 bytes
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
ARRAY[]
32 words
OF WORD
(64 bytes)
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Function
0002 hex
EPC length
Specifies the word size of the EPC code.
0000 to 001F hex (1 to 31)
0000 hex (Not used.)
0000 hex (Not used.)
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
EPC code
Gives the tag-specific information according
to Gen2 standards.
EPC data equivalent to the word size speci-
fied in the EPC length is set.
Function
Error code
R/W no. of the Reader/Writer communicating
with the RF Tag
0000 to 0007 hex
Communications diagnostics result
When communications diagnostics is enabled:
Set the communications diagnostics result
When communications diagnostics is dis-
abled: 0000 hex (fixed)
For details, refer to GET COMMUNICATIONS
DIAGNOSTIC INFORMATION on page 7-70.
Reception level
FFFF to FF9D hex (-1 to -99 [dBm])
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
ID data before writing
[0]: StoredPC
The upper 5 bits are the EPC word length.
[1 to 31]: EPC
All bytes of the EPC code section that
exceed the EPC word length in the
StoredPC are filled with 00 hex.
TM