7 Ethernet/IP Communications
GET TRANSMISSION POWER
Function
This command is used to check the transmission powers that are set in the Reader/Writer.
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo1/Response Information 2
RespInfo1/Response Information 3
Cnt/Update Counter
RespData/Response Data
Master
Reader/Writer
Slave
Reader/Writer
1
...
7 - 42
Data type
WORD
WORD
WORD
WORD
WORD
Data type
WORD
WORD
WORD
WORD
WORD
Transmis-
WORD
sion power
(Read)
Transmis-
WORD
sion power
(Write)
Transmis-
WORD
sion power
(Read)
Transmis-
WORD
sion power
(Write)
...
...
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Size
2 bytes
3004 hex
2 bytes
Number of words in transmission power set-
tings
0002 to 0010 hex
* Number of Readers/Writers x 2 words
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
2 bytes
Expresses the transmission power for read
RF communications commands.
000F to 001B hex (15 to 27 dBm)
Default setting: 001B hex
2 bytes
Expresses the transmission power for write
RF communications commands.
000F to 001B hex (15 to 27 dBm)
Default setting: 001B hex
2 bytes
Expresses the transmission power for read
RF communications commands.
000F to 001B hex (15 to 27 dBm)
Default setting: 001B hex
2 bytes
Expresses the transmission power for write
RF communications commands.
000F to 001B hex (15 to 27 dBm)
Default setting: 001B hex
...