Omron V780-Series User Manual page 213

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

SET TIME INFORMATION
Function
This command sets the time information in the Reader/Writer.
When the Reader/Writer is restarted, the time information is reset. (All zeros will be set for the actual
time flag, hour, minutes, and seconds.)
Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
Reserved/Reserved Area
Cnt Response/Update Counter
Response
CmdData/Command Data
Time informa-
tion
Response Area
Signal/data
ErrCode/Command Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespInfo3/Response Information 3
Cnt/Update Counter
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Data type
WORD
WORD
WORD
WORD
WORD
Resv
BYTE
Hour
BYTE
Minutes
BYTE
Seconds
BYTE
Data type
WORD
WORD
WORD
WORD
WORD
7 Ethernet/IP Communications
Size
2 bytes
4005 hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (At command execution)
The value is counted up due to a change in
the update counter.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
1 byte
Always 00 hex.
1 byte
Hour
0 to 23
1 byte
Minutes
0 to 59
1 byte
Seconds
0 to 59
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
2 bytes
0000 to FFFF hex
The value is counted up due to a change in
the response area.
For details, refer to Update Counter/Update
Counter Response on page 7-10.
TM
) (Z402)
Function
Function
7 - 61
7

Advertisement