6-10-4 Communications Conditions During Multi-Reader/Writer Use - Omron V780-Series User Manual

Uhf rfid system reader/writer ethernet/ip
Table of Contents

Advertisement

6 Functions

6-10-4 Communications conditions during Multi-Reader/Writer use

While the Multi-Reader/Writer is enabled, the master Reader/Writer communications conditions can be
set for each individual slave Reader/Writer or globally set for all Reader/Writers. The various setting
items are as follows:
Setting
classification
SET TAG COM-
MUNICATIONS
CONDITIONS
(Basic)
SET TAG COM-
MUNICATIONS
CONDITIONS
(Advanced)
6 - 74
Setting item
Communications mode
Communications speed
Communications timeout
time
Write verify
RF communication diag-
nostics
Transmission power
Channel
Gen2 Session
Access password
Transmission time
RSSI filter
RF Tag select filter
Smoothing buffer
UHF RFID System V780-series Reader/Writer User's Manual (EtherNet/IP
Description
Global
Global
Global
The "RF Communications Timeout Time" setting
of the master Reader/Writer is the timeout time
relative to the total communications processing
in conjunction with multiple Reader/Writers.
Global
Global
The diagnostics function is disabled.
Individual
The transmission power of the slaves is main-
tained by the master Reader/Writer.
Global
Global
Global
Global
Individual
Set individually in each Reader/Writer before
enabling Multi-Reader/Writer.
Global
Global
Remarks
TM
) (Z402)

Advertisement

Table of Contents
loading

Table of Contents