Measurement Mode and Measurement Start Timing

The procedure for specifying the measurement start timing can be selected from the following three modes.
Use these modes to synchronize the measurement timing between sensors or to perform synchronization
control with a servomotor or other external devices.
Item
Setting item
Sensor settings
Measurement
mode
 Multi View Explore
→ Edit pane
1
Set [Measurement mode].
Important
• Measures one by one input the external Trigger signal in External synchronous measurement mode.
• Need to input the external Trigger signal depending on the setting content of the filtering process.
Example)
When you set the Average number to 128, need the external Trigger signal to input 128 counts.
• When you set the Exposure control mode to Auto, multiple inputs of external Trigger signal are necessary after
adjusting the measurement object within the measurement range for optimization of exposure status.
• The following items use parameters from External/PDO synchronous measurement mode, or outside of the Internal
synchronous measurement mode so separate settings by mode is possible.
Item
Average number of times
Differentiation filter
Trigger delay mode
Note
3-1 EtherCAT Connection in Confocal Fiber Type Displacement Sensor ZW-7000 series User's Manual for
Communication settings (Cat. No. Z363).
ZW-7000/5000
User's Manual
Setting value
Description
Internal synchronous
The measurement start timing is automatically determined
measurement mode (initial
according to the set measurement cycle intervals.
value)
Use this mode to perform measurements continuously with a sensor
only or to shorten the measurement cycle as much as possible.
External synchronous
The measurement start timing is specified by TRIG input signals.
measurement
Use this mode to perform measurements in synchronization with
external signals from parallel I/O.
One measurement is performed for each TRIG input signal. In the 2
area mode, measurements for 2 areas are performed continuously.
PDO synchronized mode
The measurement start timing is determined by Sync0 signals*
automatically sent from the EtherCAT master. Use this mode to
perform measurements by synchronizing the EtherCAT slave and
EtherCAT master slave.
: [System] (double-click)
: [Sensor Settings] icon (
Setting item
Average number of times
Differentiation cycle
Delay time
Sampling time
)
Setting the Measurement Start Timing
89