Omron ZW-7000 Series User Manual page 269

Confocal fiber type displacement sensor
Hide thumbs Also See for ZW-7000 Series:
Table of Contents

Advertisement

Item
Main functions Exposure time
Measuring cycle
Material setting
Measurement item
Filtering
Output
Display
Number of configurable banks
Task process
System
Rating
Power supply voltage
Current consumption
Insulation resistance
Dielectric strength
Environmental
Degree of protection
resistance
Vibration resistance (destructive)
Shock resistance (destructive)
Ambient temperature range
Ambient humidity range
Grounding
Material
Weight
Accessories
The Export Trade Control Order compatible Controller (ZW-7000T/5000T) is available.
When using this Controller, the minimum resolution is 0.25 μm regardless of the connected Sensor Head and setting conditions.
*1:
When an extension fiber cable of 5 m or longer is connected, the setting rage of the measurement cycle (exposure time) changes. For
details, refer to "Setting Measurement Cycle" in this manual.
ZW-7000/5000
User's Manual
Specifications
ZW-7000@
Automatic/Fixed
*1
20 μs to 400 μs
Standard/Mirror/Rough surfaces
Height/Thickness of transparent object/Calculation
Median/Average/Differentiation/High pass/Low pass/Band pass
Scaling/Different holds/Zero reset/Logging for a measured value
Measured value/Threshold value/Analog output voltage or current value/
Judgment result/Resolution/Light power/Internal logging condition
/Peak amount of received light
Max. 8 banks
Multi-task (up to 4 tasks per bank)
Save/Initialization/Display measured information/Communication settings/
Sensor head calibration/Key-lock/Zero reset memory/Timing input
21.6 to 26.4 VDC (including ripple)
800 mA max.
Across all lead wires and FG terminal: 20 MΩ (by 250 VDC)
Between all lead wires and FG terminal: 500 VAC, 50/60 Hz, 1 minute
IP20 (IEC60529)
10 to 55 Hz (half amplitude 0.35 mm), 50 mins in each of X/Y/Z directions
2
150 m/s
, 6 direction, 3 times each (up/down, left/right, forward/backward)
Operation: 0 to 40°C, Storage: -15 to +60°C
(No freezing and condensation)
Operation/storage: 35 to 85% RH (No condensation)
D-type grounding (grounding resistance of 100 Ω or less)
Note: For conventional Class D grounding
Chassis: PC
Approx. 900g (main unit only), Approx. 150 g (Parallel cable)
Parallel cable (ZW-XCP2E)
10 Fiber cleaners (ZW-XCL)
Instruction Manual
Member registration sheet
ZW-5000@
80 µs to 1600 µs
Parallel cable (ZW-XCP2E)
10 Fiber cleaners (ZW-XCL)
Fiber adapter cap
Strap
Instruction Manual
Member requistration sheet
Specifications and External Dimensions
267

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zw-5000 series

Table of Contents