Emc Directive Conformity - Omron ZW-7000 Series User Manual

Confocal fiber type displacement sensor
Hide thumbs Also See for ZW-7000 Series:
Table of Contents

Advertisement

Important
Secure a minimum bending radius (R) for the cable that is at least as large as the specification value. If the bending
radius is smaller than the specification value, this can cause damage to the cable.
Parallel cable
l ZW-XCP2E
B1
B16
Item
Applicable Controller
Ambient temperature
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance (destructive)
Shock resistance (destructive)
Material
Cross section of flat cable
Core wire pitch
Cable minimum bending radius
Weight
Accessories
Important
Secure a minimum bending radius (R) for the cable that is at least as large as the specification value. If the bending
radius is smaller than the specification value, this can cause damage to the cable.

EMC Directive Conformity

CE Marking
Conformed
278
Specifications and External Dimensions
6
7
A1
A16
Specifications
ZW-7000@/ZW-5000@
Operation: 0 to 50°C, Storage: -15 to +60°C
(No freezing and condensation)
Operation/storage: 35 or 85% RH (No condensation)
1000 VAC, 50/60 Hz, 1 min
20 MΩ (by 250 VDC megger)
10 to 55 Hz (half amplitude 0.35 mm), 50 mins in each of X/Y/Z directions
2
150 m/s
Cable sheath: PVC
AWG28
1.27 mm
5.5 mm
Approx. 150 g
Instruction Manual
Applicable directive
Low voltage directive
Not applicable
2110
(13.1)
, 6 direction, 3 times each (up/down, left/right, forward/backward)
EMC directive
Conformed
(Unit: mm)
+140
0
Safety category
B
ZW-7000/5000