24 V input terminal block
Used for 24 VDC power supply.
Compatible cable specifications: Solid wire 0.2 to 2.5 mm
Class
Power Supply
Important
• Wiring with the power on could result in a short-circuit or electric shock. Wire with the power off.
• Wire the power supply separate from other devices. Wiring together with other devices or using the same duct could
cause a false operation or damage the sensor.
• Do not turn off the power during initial processing immediately after the Sensor Controller power is turned on, as the
memory inside the Sensor Controller is being accessed. This may corrupt the data.
• Securely fasten the terminal block to prevent injury when you press in the release button with a screwdriver.
• Use the electric cable within 2m.
74
Wiring
Stranded wire 0.2 to 2.5 mm
Stranded wire with rod terminal(no plastic sleeve) 0.25 to 2.5 mm
Stranded wire with rod terminal(with plastic sleeve) 0.25 to 2.5 mm
AWG 24 to 12
Pin processed length 10 (±0.5) mm
No.
1
2
Name
Description
DC24V (+)
Terminal for external power supply (24 V)
DC24V (−)
Terminal for external power supply (0 V)
2
2
Signal name
DC24V (−)
DC24V (+)
2
2
ZW-7000/5000
User's Manual