Item
Setting item
Area follow set-
Area follow
tings
Reference edge Edge1/Edge2/
Following edge
 Multi View Explorer
→ Edit Pane
→ Sensing settings window
1
Set [Area follow].
2
Set [Reference edge] and [Following edge].
3
Click [Area Teach].
The area range suitable for measuring the
following edge is automatically set as Area 2,
then Area follow starts.
Important
An error occurs if Area Teach is executed under the following conditions.
• The reference edge or the following edge cannot be measured
• The reference edge number and the following edge number are the same
124
Setting Sensing
Setting value
Description
None (initial
Area follow is not set. Select this to set any desired value.
value)
Upper line
Follows the upper line of Area 2 only.
Lower line
Follows the lower line of Area 2 only.
Upper line and
Follows the upper line and lower line of Area 2.
lower line
Select the measurement surface of measurement area 1 to be used as the
Edge3/
reference for automatic tracking.
Edge4/peak
The peak is the surface of all measurement surfaces having the highest
(Initial value:
received light amount.
Edge1)
Edge1/Edge2/
Select the measurement surface of measurement area 1 to be the target of
Edge3/Edge4/
automatic following. Measurement area 2 is automatically set based on the
peak
surface selected when [Area Teach] is clicked.
(Initial value:
The peak is the surface of all measurement surfaces having the highest
Edge2)
received light amount.
: [BANK] | [(Bank Data Name)] (double-click)
: [Sensing setting] icon (
: [measurement area 2] - Area follow settings
Area2
Area1
)
Area2
Area1
ZW-7000/5000