Output circuit
Item
Specifications
Model
ZW-7000@/5000@
*1
Output type
For NPN connection
Output voltage
DC21.6 to 30 V
Load current
50 mA max.
ON residual voltage
2 V max.
ON leakage current
0.1 mA max.
*2
Internal circuit diagram
*1 NPN/PNP dual type. According to the specifications of the external equipment, ensure proper wiring.
*2 Below is a table giving the COM_OUT (output common) and output signal connection correspondence.
Terminal name COM_OUT1
HIGH
PASS
LOW
Output signal
name
ALARM
BUSY
ENABLE
Important
• Connect a load that matches the output specifications. Short-circuit can cause sensor breakdown.
• Keep the load current less than or equal to the specification value. Exceeding the specification value could cause
damage to the output circuit.
ZW-7000/5000
User's Manual
Internal
circuit
COM_OUT2
BANK_OUT1
BANK_OUT2
BANK_OUT3
For PNP connection
DC21.6 to 30 V
50 mA max.
2 V max.
0.1 mA max.
Output
terminals
L
Load
Internal
+
circuit
COM_OUT1/2/3
COM_OUT3
STABILITY
LOGERR
LOGATAT
SYNCFLG/TRIGBUSY
TASKSTAT
COM_OUT1/2/3
+
Load
L
Output
terminals
77