Important
Frequency filter is applicable the measurement result executed TRIG input/Sync0 signal even if select the External/
PDO synchronous measurement mode. In this case, the sampling interval of measured result is used the
measurement cycle value which has been set and executed external TRIG input/Sync0 signal.
The value is not dependent on the interval which is actually executed TRIG input/Sync0 signal.
Setting the Differentiation Filter
Set this filter to detect sudden changes in measured values occurring within an extremely short time.
The differentiation filter detects changes in the measured value and current value before a comparison interval.
The time of this comparison interval is defined as the differential cycle. (Default value: OFF)
Item
Setting item
Differentiation
Filter mode
filter
Differentiation cycle
 Multi View Explore
→ Edit pane
→ Task Settings window : [Filter]
Internal synchronous
measurement mode
Present value
Sampling
Measuring cycle
Display value
(differentiation result)
142
Setting the Output Conditions
Setting value
OFF (default value)/ON
• Internal synchronous measurement mode
0.02(default value) to 5000[ms]
• External/PDO synchronous measurement
mode
1(default value) to 50000[measurement
count]
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Comparison interval: 10 ms
Description
Set the differentiation filter ON/OFF.
Set the interval(time) which performs
comparison with the current value.
Set the interval(measurement count)
which performs comparison with the
current value.
)
ZW-7000/5000
User's Manual