4-1 Setting Sensing
Setting the Measurement Cycle
Set the measurement cycle. Extending the measurement cycle allows you to measure workpieces with lower
reflectivity.
Item
Setting item
RUN mode
Measurement
Cycle
Sensor Controller
type
ZW-7000@
ZW-5000@
Multi View Explore
→ Edit pane
→ Sensing settings window : [Operating mode]
1
Set [Measurement cycle].
Important
If changing the extension fiber cable length setting causes the setting value of the measurement cycle to exceed the
maximum value, the setting value is automatically changed to the maximum value.
You can set the Measurement cycle by using key operation of the Sensor Controller p.197.
116
Setting Sensing
Setting value
Refer to the table below.
Extension fiber cable
Minimum value (1 area
length
mode) [µs.]
None
20
2m
5m
10m
20m
30m
None
80
2m
5m
10m
20m
30m
: [Bank] | [(Bank data name)] (double-click)
: [Sensing setting] icon (
Description
Set the measurement cycle.
Minimum value (2 area
Maximum value
mode) [µs.]
[µs.]
40
400
400
400
250
160
120
80
1600
1600
1600
1400
900
650
)
Initial value [µs.]
200
200
200
100
80
60
800
800
700
450
250
200
ZW-7000/5000
User's Manual