Secure a minimum bending radius (R) for the cable that is at least as large as the specification value. If the bending
radius is smaller than the specification value, this can cause damage to the cable.
Parallel cable
ZW-XCP2E
7
B1
A1
B16
A16
Item
Applicable Controller
Ambient temperature
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance (destructive)
Shock resistance (destructive)
Material
Cross section of flat cable
Core wire pitch
Cable minimum bending radius
Weight
Accessories
Important
Secure a minimum bending radius (R) for the cable that is at least as large as the specification value. If the bending
radius is smaller than the specification value, this can cause damage to the cable.

EMC Directive Conformity

CE Marking
Applicable directive
Low voltage directive
Conformed
Not applicable
ZW-7000 User's Manual
(13.1)
6
Specifications
ZW-7000@
Operation: 0 to +50°C, Storage: -15 to +60°C
(No freezing and condensation)
Operation/storage: 35 or 85% RH (No condensation)
1000 VAC, 50/60 Hz, 1 min
20 MΩ (by 250 VDC megger)
10 to 55 Hz (half amplitude 0.35 mm), 50 mins in each of X/Y/Z directions
2
150 m/s
, 6 direction, 3 times each (up/down, left/right, forward/backward)
Cable sheath: PVC
AWG28
1.27 mm
5.5 mm
Approx. 150 g
Instruction Manual
+140
2110
0
(Unit: mm)
Safety category
EMC directive
Conformed
B
Specifications and External Dimensions