Hydraulic Tank - Genie S-105 Service Manual

Hide thumbs Also See for S-105:
Table of Contents

Advertisement

Section 4 • Repair Procedures
FUEL AND HYDRAULIC TANKS
11-2

Hydraulic Tank

The primary functions of the hydraulic tank are to
cool, clean and deaerate the hydraulic fluid during
operation. It utilizes internal suction strainers for
the pump supply lines and has an external return
line filter with a filter condition indicator.
How to Remove the
Hydraulic Tank
Component damage hazard. The
work area and surfaces where this
procedure will be performed must
be clean and free of debris that
could get into the hydraulic
system.
Note: When removing a hose assembly or fitting,
the O-ring on the fitting and/or hose end must be
replaced and then torqued to specification during
installation.
Refer to Section Two, Hydraulic Hose and Fitting
Torque Specifications.
1 Remove the ground controls side turntable
cover. See 5-1, How to Remove a Hinged
Turntable Cover.
4 - 126
2 Close the two hydraulic shutoff valves located at
the hydraulic tank.
3 Remove the drain plug from the hydraulic tank
and allow all of the oil from the tank to drain into
a suitable container. See capacity
specifications.
S-100 • S-105 • S-120 • S-125
open
closed
Component damage hazard. Be
sure that the hydraulic tank shutoff
valves are in the
OPEN
before priming the pump. The
engine must not be started with
the hydraulic tank shutoff valves in
the
position or component
CLOSED
damage will occur. If the hydraulic
tank shutoff valves are closed,
remove the key from the key
switch and tag the machine to
inform personnel of the condition.
Part No. 102916
June 2011
REV A
position