Turntable Rotation Components; Turntable Rotation Hydraulic Motor And Drive Hub - Genie S-105 Service Manual

Hide thumbs Also See for S-105:
Table of Contents

Advertisement

Section 4 • Repair Procedures

Turntable Rotation Components

12-1
Turntable Rotation Hydraulic
Motor and Drive Hub
How to Remove the Turntable
Rotation Hydraulic Motor
Note: When removing a hose assembly or fitting,
the O-ring on the fitting and/or hose end must be
replaced and then torqued to specification during
installation. Refer to Section Two, Hydraulic Hose
and Fitting Torque Specifications.
1 Secure the turntable from rotating with the
turntable rotation lock pin.
unlocked
2 Remove the ground controls side fixed turntable
cover. See 5-1, How to Remove a Fixed
Turntable Cover.
4 - 128
3 Tag, disconnect and plug the hydraulic hoses
4 Remove the motor/brake mounting fasteners.
locked
S-100 • S-105 • S-120 • S-125
from the manifold that is mounted to the motor.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to squirt
or spray.
Remove the motor from the brake.
a
motor
b
motor/brake mounting bolts
c
brake
d
drive hub mounting bolts
e
drive hub
June 2011
REV A
a
b
c
e
d
Part No. 102916

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-100S-125S-120

Table of Contents