Manifold Plug Torque Specifications - Genie S-105 Service Manual

Hide thumbs Also See for S-105:
Table of Contents

Advertisement

Section 2 • Specifications
SPECIFICATIONS
Seal-Lok® fittings
1 Replace the O-ring. The O-ring must be replaced
anytime the seal has been broken. The O-ring
cannot be re-used if the fitting or hose end has
been tightened beyond finger tight.
Note: The O-rings used in the Parker Seal Lok®
fittings and hose ends are custom-size O-rings.
They are not standard SAE size O-rings. They are
available in the O-ring field service kit (Genie part
number 49612).
2 Lubricate the O-ring before installation.
3 Be sure that the face seal O-ring is seated and
retained properly.
4 Position the tube and nut squarely on the face
seal end of the fitting and tighten the nut finger
tight.
5 Tighten the nut or fitting to the appropriate
torque per given size as shown in the table.
6 Operate all machine functions and inspect the
hoses and fittings and related components to
confirm that there are no leaks.
Seal-Lok
(hose end)
SAE Dash size
-4
-6
-8
-10
-12
-16
-20
-24
2 - 22
Fittings
®
Torque
18 ft-lbs / 24.4 Nm
30 ft-lbs / 40 Nm
40 ft-lbs / 55 Nm
60 ft-lbs / 80 Nm
85 ft-lbs / 115 Nm
110 ft-lbs / 150 Nm
140 ft-lbs / 190 Nm
180 ft-lbs / 245 Nm
S-100 • S-105 • S-120 • S-125
Manifold Plug Torque
Specifications
Plug torque
SAE No. 2
SAE No. 4
SAE No. 6
SAE No. 8
SAE No. 10
SAE No. 12
June2011
REV E
50 in-lbs / 6 Nm
14 ft-lbs / 18.9 Nm
23 ft-lbs / 31.2 Nm
36 ft-lbs / 48.8 Nm
62 ft-lbs / 84.1 Nm
84 ft-lbs / 113.9 Nm
Part No. 102916