4 Close the control box lid.
5 Remove the decal from the platform control box.
6 Carefully remove the membrane decal from the
platform control box while guiding the ribbon
cables out of the control box lid.
7 Remove any decal adhesive from the control
box lid with a mild solvent.
Note: Do not allow any solvent to come in contact
with the membrane circuit board.
8 Install the new membrane decal (Genie part
number 50810) while guiding the ribbon cables
through the control box lid.
Note: Be sure that all LED locations on the
membrane decal align with the LED's on the
membrane circuit board.
9 Install a new platform controls decal (Genie part
number 65182) over the membrane decal.
10 Open the control box lid and carefuly connect
the ribbon cables from the membrane decal to
the membrane circuit board.
Part No. 102916
1-3
Joysticks
How to Calibrate a Joystick
The joystick controllers on this machine utilize
digital Hall Effect technology for proportional
control. If a joystick controller is disconnected or
replaced, it must be calibrated before that particular
machine function will operate.
Note: The joystick must be calibrated before the
threshold, max-out or ramp rate can be set.
Note: It is possible to reset multiple joystick
defaults before exiting the programming mode.
Note: After each joystick is calibrated, check the
display at the ground control box. There should be
no calibration faults shown on the display. If
calibration faults exist, repeat steps 1 through 8 for
that joystick controlled function.
Note: Contact Genie Industries Service Department
before using the reset all joystick default option.
Note: Perform this procedure with the engine off.
The calibration procedure for each joystick begins
on the next page.