MX2020 3D Universal Edge Router Hardware Guide
MX2020 Three-Phase Wye AC Power Distribution Module Description
88
Each three-phase wye AC PDM weighs approximately 12 lb (5.44 kg). A metal wiring
compartment contains two AC terminal blocks and ground labeled
block consists of three input terminals that serves six PSMs and the second terminal
block serves three PSMs. The terminal block on the far left is labeled
(bottom to top). The second terminal block is labeled
The PDMs are located at the rear of the chassis in slots
PDM3/Input1
, (bottom to top). LEDs provide the status of the PDM.
shows the three-phase wye AC PDM.
NOTE:
The three-phase wye AC PDM terminal blocks will be flipped
depending on which slot the PDM gets plugged into.
Figure 40: Three-Phase Wye AC Power Distribution Module
Figure 41 on page 89
shows the three-phase wye AC PDM connections.
NOTE:
The three-phase wye AC PDM must be installed and secured in the
chassis before connecting the power input cables. If the PDM must be
removed, both input power cables must be uninstalled and removed from
the PDM before the PDM can be removed from the chassis. The MX2020
chassis is not sensitive to phase rotation sequence—either CW or CCW will
operate correctly.
. One AC terminal
GND
,
,
, and
A1
B1
C1
,
,
, and
(bottom to top).
A2
B2
C2
N2
through
PDM0/Input0
Figure 40 on page 88
Copyright © 2015, Juniper Networks, Inc.
N1