CHAPTER 14
DC Power Requirements, Specifications,
and Guidelines

MX2020 DC Power Requirements

Copyright © 2015, Juniper Networks, Inc.
MX2020 DC Power Requirements on page 171
MX2020 DC Power Distribution Description on page 177
MX2020 DC Power Subsystem Electrical Specifications on page 179
Calculating DC Power Requirements for MX2020 Routers on page 180
DC Power Circuit Breaker Requirements for the MX2020 Router on page 184
DC Power Cable Specifications for the MX2020 Router on page 184
Table 66 on page 172
lists the FRU power requirements for SFBs, CB-REs, MPCs, and
MICs. In addition,
Table 66 on page 172
optics at various operating temperatures.
Typical power represents power under certain temperatures and normal operating
conditions.
For PDMs with 60 A feeds, we recommend that you select the 60 A @ –48 VDC switch
for each input.
For PDMs with 80 A feeds, we recommend that you select the 80 A @ –48 VDC switch
for each input.
If you do not plan to provision as recommended above, you can use the information in
Table 66 on page 172
to calculate the power consumption for your hardware configuration.
NOTE:
Unlike all the other MPCs, MPC6E does not require an adapter card
(ADC) to house the MPC in the MX2020 router.
lists the MPC power requirements with MICs and
171