Copyright © 2015, Juniper Networks, Inc.
Figure 238: Three-Phase Delta AC Power Cord
Remove the ESD grounding strap from the approved site ESD grounding point. See
6.
the instructions for your site. Reconnect the strap to one of the ESD points on the
chassis.
Using a number 2 Phillips (+) screwdriver, loosen the four screws on the cover of the
7.
metal wiring compartment that protects the AC terminal block.
Remove the cover of the metal wiring compartment.
8.
Disconnect the wires from the AC terminal block on the three-phase delta AC PDM
9.
(see
Figure 239 on page
screws, and remove each wire from the grounding point or input terminal.
NOTE:
The terminal connections have either slotted screws or hex screws.
Use a 1/4-in. slotted screwdriver for the slotted screws. Use a 5/32-in.
(4 mm) Allen wrench for the 5/16-in. hex screws.
To remove wires from the terminal block that serves six PSMs:
a. Remove the wire labeled
b. Remove the wire labeled
c. Remove the wire labeled
d. Remove the grounding wire from the grounding point labeled
506). Loosen each of the input terminals or grounding point
L3
from the input terminal labeled
from the input terminal labeled
L2
L1
from the input terminal labeled
Chapter 25: Replacing Components
C1
.
.
B1
A1
.
.
GND
505