3 — Troubleshooting network alarms
Alarm name, ID, type, and probable
cause(s)
Alarm name: SoftwareFailureAlarm
Alarm ID: 149
Type: softwareAlarm (19)
Probable cause: loadFailed (124)
Alarm name: SSHServerPreserveKeyFailure
Alarm ID: 406
Type: softwareAlarm (19)
Probable cause: preserveKeyFailure (302)
Alarm name: SWIncompatibility
Alarm ID: 471
Type: configurationAlarm (11)
Probable cause:
elementNotCompatibleWithExistingStack
(357)
Alarm name: TemperatureThresholdCrossed
Alarm ID: 7
Type: environmentalAlarm (2)
Probable cause: equipmentOverheated (5)
Alarm name: upgradedCardAlarm
Alarm ID: 255
Type: softwareAlarm (19)
Probable cause: upgradedCard (194)
Alarm name: XplError
Alarm ID: 573
Type: hardwareAnomaly (55)
Probable cause: xplError (443)
(10 of 10)
Alarm name, ID, type, and probable
cause(s)
Alarm name: EthernetPortHighBer
Alarm ID: 307
Type: communicationsAlarm (4)
Probable cause: HighBer (238)
Alarm name: EthernetPortLocalFault
Alarm ID: 305
Type: communicationsAlarm (4)
Probable cause: LocalFault (236)
(1 of 2)
3-36
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Critical
Object Type (class): ReplaceableUnit
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Critical
Object Type (class): FlashMemory
Domain: equipment
Self-clearing alarm raised: No
Severity: Major
Object Type (class):
StackConfiguration
Domain: equipment
Self-clearing alarm raised: No
Severity: Major
Object Type (class): Environment
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): Card
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Self-clearing alarm raised: Yes
Table 3-12 Domain: ethernetequipment
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Major
Object Type (class):
EthernetPortSpecifics
Domain: ethernetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
EthernetPortSpecifics
Domain: ethernetequipment
Self-clearing alarm raised: Yes
November 2008
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
Additional information
The alarm is raised when the CPM
fails to load the software from the
specified location. The alarm lists
the location of the software.
The alarm is raised when the CPM
module fails to save the SSH server
host key on the persistent drive.
Indicates that the current slot will
enter the pass through mode because
it is not compatible with the existing
stack.
To display the temperature
threshold, choose
Application→Equipment
Manager→Cards tab→Environment.
The upgraded card alarm is raised
against the standby CPM when the
standby CPM is rebooted and online.
The IOM cards are rebooted
automatically after 120 minutes if
they are not rebooted manually after
a CPM upgrade.
Generated when an MDA exhibits
persistent XPL Errors.