Alcatel-Lucent 5620 Troubleshooting Manual page 67

Service aware manager
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm name, ID, type, and probable
cause(s)
Alarm name: ConfigNotCompatible
Alarm ID: 405
Type: equipmentAlarm (3)
Probable cause:
DaughterCardConfigNotCompatible (301)
Alarm name:
ContainingEquipmentAdministrativelyDown
Alarm ID: 466
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentAdministrativelyDown
(330)
Alarm name: ContainingEquipmentMismatch
Alarm ID: 464
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentMismatch (328)
Alarm name: ContainingEquipmentMissing
Alarm ID: 463
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentMissing (327)
Alarm name:
ContainingEquipmentOperationallyDown
Alarm ID: 465
Type: equipmentAlarm (3)
Probable cause: containingEquipmentDown
(329)
Alarm name: DataLossAlarm
Alarm ID: 148
Type: storageAlarm (25)
Probable cause: dataLoss (122)
Alarm name:
DaughterCardConfigNotCompatible
Alarm ID: 404
Type: equipmentAlarm (3)
Probable cause:
DaughterCardConfigNotCompatible (301)
Alarm name: DDMAux1HighAlarm
Alarm ID: 495
Type: thresholdAlarm (49)
Probable cause: aux1HighAlarm (381)
Alarm name: DDMAux1HighWarning
Alarm ID: 494
Type: thresholdAlarm (49)
Probable cause: aux1HighWarning (380)
(3 of 10)
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
3HE 04244 AAAB Ed. 01
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Severity: Minor
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): FlashMemory
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Critical
Object Type (class):
DaughterCardSlot
Domain: equipment
Self-clearing alarm raised: No
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Self-clearing alarm raised: Yes
Troubleshooting Guide
3 — Troubleshooting network alarms
Additional information
The alarm is raised when the
daughter card configuration is not
compatible.
An error has occurred while writing
to the compact flash on the router.
This indicates a probable data loss.
Check the compact flash capacity on
the router.
November 2008
3-29

Advertisement

Table of Contents
loading

Table of Contents