Alarm name, ID, type, and probable
cause(s)
Alarm name: ConfigNotCompatible
Alarm ID: 405
Type: equipmentAlarm (3)
Probable cause:
DaughterCardConfigNotCompatible (301)
Alarm name:
ContainingEquipmentAdministrativelyDown
Alarm ID: 466
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentAdministrativelyDown
(330)
Alarm name: ContainingEquipmentMismatch
Alarm ID: 464
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentMismatch (328)
Alarm name: ContainingEquipmentMissing
Alarm ID: 463
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentMissing (327)
Alarm name:
ContainingEquipmentOperationallyDown
Alarm ID: 465
Type: equipmentAlarm (3)
Probable cause: containingEquipmentDown
(329)
Alarm name: DataLossAlarm
Alarm ID: 148
Type: storageAlarm (25)
Probable cause: dataLoss (122)
Alarm name:
DaughterCardConfigNotCompatible
Alarm ID: 404
Type: equipmentAlarm (3)
Probable cause:
DaughterCardConfigNotCompatible (301)
Alarm name: DDMAux1HighAlarm
Alarm ID: 495
Type: thresholdAlarm (49)
Probable cause: aux1HighAlarm (381)
Alarm name: DDMAux1HighWarning
Alarm ID: 494
Type: thresholdAlarm (49)
Probable cause: aux1HighWarning (380)
(3 of 10)
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
3HE 04244 AAAB Ed. 01
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Severity: Minor
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Port
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): FlashMemory
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Critical
Object Type (class):
DaughterCardSlot
Domain: equipment
Self-clearing alarm raised: No
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Self-clearing alarm raised: Yes
Troubleshooting Guide
3 — Troubleshooting network alarms
Additional information
The alarm is raised when the
daughter card configuration is not
compatible.
—
—
—
—
An error has occurred while writing
to the compact flash on the router.
This indicates a probable data loss.
Check the compact flash capacity on
the router.
—
—
—
November 2008
3-29