Alarm name, ID, type, and probable
cause(s)
Alarm name: SubnetMinFreeExc
Alarm ID: 516
Type: configurationAlarm (11)
Probable cause:
actualFreeAddrBelowSubnetMin (391)
Alarm name, ID, type, and probable
cause(s)
Alarm name: AncillaryPathLimitReached
Alarm ID: 459
Type: resourceAlarm (28)
Probable cause: resourceLimitReached
(131)
Alarm name: BackgroundDiagnosticFault
Alarm ID: 467
Type: equipmentAlarm (3)
Probable cause: backgroundDiagnosticFault
(353)
Alarm name: BatmDsx1CurrentCSSs
Alarm ID: 336
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Alarm name: BatmDsx1CurrentESs
Alarm ID: 330
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Alarm name: BatmDsx1CurrentLESs
Alarm ID: 326
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Alarm name: BatmDsx1CurrentPVCs
Alarm ID: 328
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Alarm name: BatmDsx1CurrentSEFSs
Alarm ID: 334
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
(1 of 10)
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
3HE 04244 AAAB Ed. 01
Table 3-10 Domain: dhcp
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Warning
Object Type (class): Subnet
Domain: dhcp
Self-clearing alarm raised: No
Table 3-11 Domain: equipment
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Minor
Object Type (class): ReplaceableUnit
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: No
Troubleshooting Guide
3 — Troubleshooting network alarms
Additional information
The alarm is raised when the actual
number of free addresses in a subnet
falls below the desired minimum
number specified in the subnet
configuration.
Additional information
The alarm is raised when the
threshold is crossed for the current
number of Far End Controlled Slip
Seconds.
The alarm is raised when the
threshold is crossed for the current
number of Far End Errored Seconds.
The alarm is raised when the
threshold is crossed for the current
number of Line Errored Seconds.
The alarm is raised when the
threshold is crossed for the current
number of Path Coding Violations.
The alarm is raised when the
threshold is crossed for the current
number of Far End Severely Errored
Framing Seconds.
November 2008