Alarm name, ID, type, and probable
cause(s)
Alarm name: HardwareRedundancyAlarm
Alarm ID: 147
Type: equipmentAlarm (3)
Probable cause: primaryCpmFailure (121)
Alarm name: LagPortAddFailed
Alarm ID: 422
Type: equipmentAlarm (3)
Probable cause: linkDown (315)
Alarm name: LinkDown
Alarm ID: 12
Type: communicationsAlarm (4)
Probable cause: portLinkProblem (10)
Alarm name: OutOfSlots
Alarm ID: 462
Type: configurationAlarm (11)
Probable cause: noAvailableSlotNumbers
(352)
Alarm name: OverTemperatureDetected
Alarm ID: 388
Type: environmentalAlarm (2)
Probable cause: equipmentOverheated (5)
Alarm name: PChipError
Alarm ID: 593
Type: hardwareAnomaly (55)
Probable cause: pChipError (447)
Alarm name: PowerSupplyRemoved
Alarm ID: 542
Type: equipmentAlarm (3)
Probable cause: PowerSupplyRemoved (415)
Alarm name: PrimaryPathLimitReached
Alarm ID: 457
Type: resourceAlarm (28)
Probable cause: resourceLimitReached
(131)
Alarm name: SecondaryPathLimitReached
Alarm ID: 458
Type: resourceAlarm (28)
Probable cause: resourceLimitReached
(131)
Alarm name: SGLimitExceeded
Alarm ID: 456
Type: resourceAlarm (28)
Probable cause:
pimSnpgSGGroupMaxSupportedLimitExceed
ed (350)
(9 of 10)
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
3HE 04244 AAAB Ed. 01
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Major
Object Type (class):
ControlProcessor
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Equipment
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): Shelf
Domain: equipment
Self-clearing alarm raised: No
Severity: Major
Object Type (class): Shelf
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): BaseCard
Domain: equipment
Self-clearing alarm raised: No
Severity: Critical
Object Type (class):
PowerSupplyTray
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Self-clearing alarm raised: Yes
Severity: Warning
Object Type (class): Card
Domain: equipment
Self-clearing alarm raised: No
Troubleshooting Guide
3 — Troubleshooting network alarms
Additional information
—
The alarm is raised when the Lag Port
Add Failed.
—
—
—
Generated when a P-chip
experiences persistent errors in
either the ingress or egress data path
or complex direction.
—
—
—
The alarm is raised when the
maximum number of PIM snooping
source group records on the card is
exceeded.
November 2008
3-35