Alcatel-Lucent 5620 Troubleshooting Manual page 124

Service aware manager
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

3 — Troubleshooting network alarms
Alarm name, ID, type, and probable
cause(s)
Alarm name:
AllTimingReferencesNotQualified
Alarm ID: 549
Type: communicationsAlarm (4)
Probable cause:
allTimingReferencesNotQualified (419)
Alarm name: BITSNotQualified
Alarm ID: 547
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Alarm name:
ExternalTimingReferenceNotQualified
Alarm ID: 548
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Alarm name: SiteSyncDeploymentFailure
Alarm ID: 589
Type: equipmentAlarm (3)
Probable cause: siteSyncFailure (441)
Alarm name:
TimingReferenceOneNotQualified
Alarm ID: 545
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
Alarm name:
TimingReferenceTwoNotQualified
Alarm ID: 546
Type: communicationsAlarm (4)
Probable cause:
timingReferenceNotQualified (418)
3-86
Table 3-53 Domain: sonet
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Major
Object Type (class): SyncReference
Domain: sonet
Self-clearing alarm raised: Yes
Severity: Minor
Object Type (class): SyncReference
Domain: sonet
Self-clearing alarm raised: Yes
Severity: Minor
Object Type (class): SyncReference
Domain: sonet
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class): SiteSync
Domain: sonet
Self-clearing alarm raised: No
Severity: Minor
Object Type (class): SyncReference
Domain: sonet
Self-clearing alarm raised: Yes
Severity: Minor
Object Type (class): SyncReference
Domain: sonet
Self-clearing alarm raised: Yes
November 2008
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
Additional information
The alarm is raised when no timing
references on the NE are in the
Qualified state.
Troubleshooting Guide