Alarm name, ID, type, and probable
cause(s)
Alarm name:
OspfLsaThresholdExceededPerRouter
Alarm ID: 374
Type: topologyAlarm (34)
Probable cause: routerAdvertisingManyLSAs
(273)
Alarm name: TooManyCpaaForIsisLevel2
Alarm ID: 384
Type: configurationAlarm (11)
Probable cause: tooManyCpaaForIsisLevel2
(288)
Alarm name: TooManyCpaaPerOspfArea
Alarm ID: 383
Type: configurationAlarm (11)
Probable cause: tooManyCpaaPerOspfArea
(287)
Alarm name: TopologyIsisSystemError
Alarm ID: 373
Type: topologyAlarm (34)
Probable cause:
isisSystemNotAdvertisingTeRouterId (272)
(4 of 4)
Alarm name, ID, type, and probable
cause(s)
Alarm name: TopologyRuleExecutionError
Alarm ID: 365
Type: configurationAlarm (11)
Probable cause: ruleErrorOrRuleEngineError
(262)
Alarm name: TunnelElementCreationError
Alarm ID: 366
Type: configurationAlarm (11)
Probable cause:
unableToCreateTunnelElement (263)
(1 of 2)
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
3HE 04244 AAAB Ed. 01
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Major
Object Type (class): Router
Domain: topology
Self-clearing alarm raised: Yes
Severity: Critical
Object Type (class): Cpaa
Domain: topology
Self-clearing alarm raised: Yes
Severity: Critical
Object Type (class): Cpaa
Domain: topology
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
AutonomousSystem
Domain: topology
Self-clearing alarm raised: Yes
Table 3-62 Domain: tunnelmgmt
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Major
Object Type (class): TopologyRule
Domain: tunnelmgmt
Self-clearing alarm raised: No
Severity: Major
Object Type (class): TopologyRule
Domain: tunnelmgmt
Self-clearing alarm raised: No
Troubleshooting Guide
3 — Troubleshooting network alarms
Additional information
Additional information
The alarm is raised when it is not
possible to execute a topology rule
or the rule execution generates an
error. In this context, rule execution
is defined as the process that
determines which tunnel elements
require creation, modification, or
deletion. The alarm typically
indicates problems with the rule
configuration.
The alarm is raised when the
creation of a missing tunnel element
fails.
November 2008
3-99