Alcatel-Lucent 5620 Troubleshooting Manual page 125

Service aware manager
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm name, ID, type, and probable
cause(s)
Alarm name: BerLineSignalDegradation
Alarm ID: 88
Type: communicationsAlarm (4)
Probable cause: berLineSignalDegradation
(74)
Alarm name: BerLineSignalFailure
Alarm ID: 89
Type: communicationsAlarm (4)
Probable cause: berLineSignalFailure (75)
Alarm name: LineAlarmIndicationSignal
Alarm ID: 84
Type: communicationsAlarm (4)
Probable cause: lineAlarmIndicationSignal
(70)
Alarm name: LineErrorCondition
Alarm ID: 94
Type: communicationsAlarm (4)
Probable cause: lineErrorCondition (80)
Alarm name: LineRemoteDefectIndication
Alarm ID: 85
Type: communicationsAlarm (4)
Probable cause:
lineRemoteDefectIndication (71)
Alarm name: LossOfClock
Alarm ID: 83
Type: communicationsAlarm (4)
Probable cause: lossOfClock (69)
Alarm name: RxSectionSynchronizationError
Alarm ID: 93
Type: communicationsAlarm (4)
Probable cause:
rxSectionSynchronizationError (79)
Alarm name: SectionB1Error
Alarm ID: 87
Type: communicationsAlarm (4)
Probable cause: sectionB1Error (73)
(1 of 3)
Alcatel-Lucent 5620 Service Aware Manager, Release 6.1 R3
3HE 04244 AAAB Ed. 01
Table 3-54 Domain: sonetequipment
Alarm severity, object type,
domain, and self-clearing attribute
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Severity: Major
Object Type (class):
SonetPortMonitorSpecifics
Domain: sonetequipment
Self-clearing alarm raised: Yes
Troubleshooting Guide
3 — Troubleshooting network alarms
Additional information
lb2er-sd reports line signal
degradation BER errors. Use the
threshold command to set the error
rate(s) that when exceeded
determine signal degradation and
signal failure. When configured,
lb2er-sd alarms are raised and
cleared. These alarms are not issued
by default.
lb2er-sf reports line signal failure
BER errors. Use the threshold
command to set the error rate(s)
that when exceeded determine
signal degradation and signal
failure.When configured, lb2er-sf
alarms are raised and cleared. These
alarms are issued by default.
Reports line alarm indication signal
LAIS errors. When configured, LAIS
alarms are raised and cleared.
Reports a line error condition raised
by the remote as a result of b1 errors
received from this node. When
configured, LREI traps are raised but
not cleared.
Reports line remote defect
indication errors. LRDIs are caused
by remote LOF, LOC, LOS. When
configured, LRDI alarms are raised
and cleared.
Reports a LOC which causes the
operational state of the port to be
shut down.
Reports section synchronization
failure as reported by the S1 byte.
When configured, SS1F alarms are
raised and cleared.
Reports a b1 line error condition
raised by the remote node when b1
errors are received from this node.
When configured, LREI traps are
raised but not cleared.
November 2008
3-87

Advertisement

Table of Contents
loading

Table of Contents